Küba Kältetechnik GmbH. Next economy line. Simple Reliable Fresh. comfort DP. market plus SP. compact DF. junior DF - PDF

Description
Küba Kältetechnik GmbH Next economy line Simple Reliable Fresh market plus SP comfort DP compact DF junior DF next economy line junior DF Ceiling Air Cooler Hygienic version Q kw H max. 180 applied

Please download to get full document.

View again

of 9
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Information
Category:

Food & Beverages

Publish on:

Views: 35 | Pages: 9

Extension: PDF | Download: 0

Share
Transcript
Küba Kältetechnik GmbH Next economy line Simple Reliable Fresh market plus SP comfort DP compact DF junior DF next economy line junior DF Ceiling Air Cooler Hygienic version Q kw H max. 180 applied for Innovations Straightforward mounting Removable fan plate Screw unit to ceiling Connect unit Re-install lower section Space-saving Horizontal drain As a result the height including 90 elbow is reduced to 180 mm 1 1 Best air guidance Integrated air baffle plate Directs the air along the ceiling of the room and therefore projects it far into the room Extreme applications Additional heating installation possible In extreme applications, e.g. in deep-freeze rooms with door openings, an additional electric heater can be retrofi ed for trouble-free operation Standard type code DF B E 02 3 C Küba Ceiling Air Cooler Distance between fins: A = 4.5 mm B = 7.0 mm Generation code C Number of fans: 1-3 El. defrosting E = with el. defrosting Size: 01, 02, 03 11 Quick selection Normal 4.5 mm 023C 033C Qo 022C 032C +4 C +2 C Load 0 C DFA(E) 031C 021C 011C 3 m m 3 033C 023C High 022C 032C 031C Qo DFA(E) 011C 021C Load 1 m m 3 Normal 033C 7.0 mm 023C Qo 022C 032C Load DFB(E) 011C 021C 031C 0 C 2 m m 3-18 C -20 C 033C 023C High 022C 032C 031C Qo DFB(E) 011C 021C Load 1 m Example: Information: Volume of room: 3 m 3 Temperature: +2 C High loading Selection: Küba junior DFA(E) 032C 4 m 3 12 next economy line junior DF Configuration Housing Aluminium, Sendzimir zinc-plated steel, smooth High-quality powder coating, papyrus white RAL 9018 Food-safe Easy to clean Best corrosion protection Double drip tray Drip tray can be folded down and unclipped Height of junior DF. only 180 mm (incl. drain) 2. Cooler Internal cleanliness acc. to DIN 8964 Distance between fins: DFA.C: 4.5 mm, DFB.C: 7.0 mm Tubing Cu-special, fins Al, end plates Al Completely powder-coated (hygienic paint) 3. Fans Fans wired up to a terminal box With built-in protector according to VDE provisions Application range: DF.C: RT -30 C to +40 C 230 V ±10 % V-1, adjustable Index of protection IP44 acc. to DIN Insulation class E acc. to VDE 0530 Operating values are the actual values of the builtin motor at +20 C, with unobstructed air flow and a dry surface, as required for the refrigeration load calculation Model plate information = Max. permi ed values at t amb +40 C, with unobstructed air flow Type 50 Hz 60 Hz Ø mm rpm W A rpm W A DF C Electrical defrosting Pre-wired, ready to connect in terminal box The heater rods are mounted between the coil and the tray for rapid and even defrosting 230 V-1 13 t L1 +20 C 4.5 mm DFA(E) C 0.5 kw 2 kw -25 C Technical data Type Power Q at 50 Hz DT1. R404A t L1 ±0 C DT1 = 8 K t L1-18 C DT1 = 7 K Cooling area Air flow Air throw Tube volume Connections Sound Fans (operating values at 50 Hz) Inlet Outlet L WA* Blades Current type Per fan kw kw m2 m3/h m dm3 Ø mm Ø mm db(a) Pcs. x Ø mm 230±10% V-1 50/60Hz a p p l i e d f o r Electr. defrosting rpm W A kw DFA 011C x V DFA 021C x V DFA 031C x V DFA 022C x V DFA 032C x V DFA 023C x V DFA 033C x V * Modification of sound power level. see page 47 See page 47 for information about Q V diagram Q v Diagram (R134a, R404A, R507) -25 t L1 [ C] Air inlet temperature C R134a t Q -12 C x 1.00 -17 C x 0.96 -22 C x 0.93 -27 C x 0.90 -27 C x 0.86 R404A= x 1.00 R507 = x 1.04 Application limit Dt1=14K Dt1=13K Dt1=12K Dt1=11K Dt1=10K Dt1=9K Dt1=8K Dt1=7K Dt1=6K Q 0 [kw] Capacity kw DFA 011C Dt1=5K Dt1=4K Frost Limit Example junior DFAE..C / DFA..C 011C 021C 031C 022C 032C 023C 033C 14 next economy line junior DF t L1 +10 C 7 mm DFB(E) C 0.4 kw 1.8 kw -25 C Technical data Type Power Q at 50 Hz DT1. R404A t L1 ±0 C DT1 = 8 K t L1-18 C DT1 = 7 K Cooling area Air flow Air throw Tube volume Connections Sound Fans (operating values at 50 Hz) Inlet Outlet L WA* Blades Current type Per fan kw kw m2 m3/h m dm3 Ø mm Ø mm db(a) Pcs. x Ø mm 230±10% V-1 50/60Hz a p p l i e d f o r Electr. defrosting rpm W A kw DFB 011C x V DFB 021C x V DFB 031C x V DFB 021C x V DFB 032C x V DFB 023C x V DFB 033C x V * Modification of sound power level. see page 47 See page 47 for information about Q V diagram Q v Diagram (R134a, R404A, R507) -25 t L1 [ C] Air inlet temperature C R134a t Q -12 C x 1.00 -17 C x 0.96 -22 C x 0.93 -27 C x 0.90 -27 C x 0.86 R404A= x 1.00 R507 = x 1.04 Application limit Dt1=14K Dt1=13K Dt1=12K Dt1=11K Dt1=10K Dt1=9K Dt1=8K Dt1=7K Dt1=6K Q 0 [kw] Capacity kw DFB 011C Dt1=5K Dt1=4K Frost Limit Example junior DFBE..C / DFB..C 011C 021C 031C 022C 032C 023C 033C 15 Dimensions and weights 20 5 Ø Ø L =380± DF. (E) 011, 021, 031C B.S E1±3 A.S 155±3 B±3 DF. (E) 022, 032C B.S E1±3 A.S 155±3 B±3 155±3 34 H±5 76 Drain G 3/4 126±3 T±5 DF. (E) 023, 033C B.S E1±3 A.S B±3 Type Dimensions (mm) Weight (net) DFA.C H B D L E1 F kg kg DF. 011C DF. 021C DF. 031C DF. 022C DF. 032C DF. 023C DF. 033C DFB.C 16 Küba products are available at Küba Kältetechnik GmbH Oberdiller Straße 23 D Baierbrunn A GEA Group company Tel.: ++49 (0)89/ Fax: ++49 (0)89/ Issue date 12/2005. Errors and omissions excepted Copyright 2005 Küba Kältetechnik GmbH
Related Search
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks