GETTING STARTED GUIDE NI AI, ±30 V, 24 Bit, ks/s/ch Simultaneous - PDF

Description
GETTING STARTED GUIDE NI AI, ±30 V, 24 Bit, ks/s/ch Simultaneous This document explains how to connect to the NI In this document, the NI 9232 with screw terminal and the NI 9232 with

Please download to get full document.

View again

of 20
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Information
Category:

Graphic Art

Publish on:

Views: 25 | Pages: 20

Extension: PDF | Download: 0

Share
Transcript
GETTING STARTED GUIDE NI AI, ±30 V, 24 Bit, ks/s/ch Simultaneous This document explains how to connect to the NI In this document, the NI 9232 with screw terminal and the NI 9232 with BNC are referred to inclusively as the NI Note Before you begin, complete the software and hardware installation procedures in your chassis documentation. Note The guidelines in this document are specific to the NI The other components in the system might not meet the same safety ratings. Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system. Safety Guidelines Operate the NI 9232 only as described in this document. Caution Do not operate the NI 9232 in a manner not specified in this document. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any 2 ni.com NI 9232 Getting Started Guide way. If the product is damaged, return it to NI for repair. Safety Voltages Connect only voltages that are within the following limits. Isolation Channel-to-channel Channel-to-earth ground Continuous Withstand None 60 VDC, Measurement Category I 1,000 Vrms, verified by a 5 s dielectric withstand test Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. NI 9232 Getting Started Guide National Instruments 3 Caution Do not connect the NI 9232 to signals or use for measurements within Measurement Categories II, III, or IV. Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV. Safety Guidelines for Hazardous Locations The NI 9232 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx na IIC T4 and Ex na IIC T4 hazardous locations; and nonhazardous locations only. Follow these guidelines if you are installing the NI 9232 in a potentially explosive environment. Not following these guidelines may result in serious injury or death. Caution Do not disconnect I/O-side wires or connectors unless power has been switched off or the area is known to be nonhazardous. 4 ni.com NI 9232 Getting Started Guide Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous. Caution Substitution of components may impair suitability for Class I, Division 2. Caution For Division 2 and Zone 2 applications, install the system in an enclosure rated to at least IP54 as defined by IEC/EN Caution For Division 2 and Zone 2 applications, connected low impedance sources must include a protection device installed between the source and the AI terminals. The protection device must prevent the AI+ to AI- voltage from exceeding 42 V if there is a transient overvoltage condition. Caution For Division 2 and Zone 2 applications, connected signals must be within the following limits. Capacitance 0.08 μf max NI 9232 Getting Started Guide National Instruments 5 Special Conditions for Hazardous Locations Use in Europe and Internationally The NI 9232 has been evaluated as Ex na IIC T4 Gc equipment under DEMKO Certificate No. 12 ATEX X and is IECEx UL X certified. Each NI 9232 is marked II 3G and is suitable for use in Zone 2 hazardous locations, in ambient temperatures of -40 C Ta 70 C. If you are using the NI 9232 in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex nc IIC T4, Ex IIC T4, Ex na IIC T4, or Ex nl IIC T4 equipment. Caution You must make sure that transient disturbances do not exceed 140% of the rated voltage. Caution The system shall only be used in an area of not more than Pollution Degree 2, as defined in IEC Caution The system shall be mounted in an ATEX/IECEx-certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC/EN ni.com NI 9232 Getting Started Guide Caution The enclosure must have a door or cover accessible only by the use of a tool. Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the product is used in residential or commercial areas. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. NI 9232 Getting Started Guide National Instruments 7 Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories. Do not use unshielded cables or accessories unless they are installed in a shielded enclosure with properly designed and shielded input/ output ports and connected to the product using a shielded cable. If unshielded cables or accessories are not properly installed and shielded, the EMC specifications for the product are no longer guaranteed. Caution Electrostatic Discharge (ESD) can damage the NI To prevent damage, use industry-standard ESD prevention measures during installation, maintenance, and operation. Caution To ensure the specified EMC performance for the NI 9232 with screw terminal, you must install clamp-on ferrite beads (part number ) in accordance with the product installation instructions. 8 ni.com NI 9232 Getting Started Guide Refer to the NI 9232 product page on ni.com for purchasing information about clamp-on ferrite beads. Caution To ensure the specified EMC performance, the length of all I/O cables must be no longer than 30 m (100 ft). Cable Requirements for EMC Compliance Select and install cables for the NI 9232 in accordance with the following requirements: Connect the cable shield to the chassis ground (grounding screw of the chassis). For the NI 9232 with screw terminal, install a clamp-on ferrite bead (part number ) on the input cable for each channel that you are connecting to on the NI For the NI 9232 with screw terminal, clamp-on ferrite beads must be installed on the cable as close to the module as possible. Placing the ferrite elsewhere on the cable noticeably impairs its effectiveness. NI 9232 Getting Started Guide National Instruments 9 Figure 1. Cable Connections for EMC Compliance Signal Source Signal Source Shield Shield Ferrite Ferrite AI0+ AI0- AI1+ AI1- Signal Source Shield Ferrite AI2+ AI2- NI 9232 with Screw Terminal Special Conditions for Marine Applications Some products are Lloyd s Register (LR) Type Approved for marine (shipboard) applications. To verify Lloyd s Register certification for a product, visit ni.com/certification and search for the LR certificate, or look for the Lloyd s Register mark on the product. 10 ni.com NI 9232 Getting Started Guide Caution In order to meet the EMC requirements for marine applications, install the product in a shielded enclosure with shielded and/or filtered power and input/output ports. In addition, take precautions when designing, selecting, and installing measurement probes and cables to ensure that the desired EMC performance is attained. Preparing the Environment Ensure that the environment in which you are using the NI 9232 meets the following specifications. Operating temperature -40 C to 70 C (IEC , IEC ) Operating humidity (IEC ) Pollution Degree 2 Maximum altitude Indoor use only. 10% RH to 90% RH, noncondensing 5,000 m NI 9232 Getting Started Guide National Instruments 11 Note Refer to the device datasheet on ni.com/manuals for complete specifications. Connecting the NI 9232 The NI 9232 provides connections to three simultaneously sampled analog input channels. 12 ni.com NI 9232 Getting Started Guide Figure 2. NI 9232 Pinout AI0+ AI0 0 1 AI0 AI0+ AI1+ AI1 0 1 AI1 AI1+ AI2+ AI2 0 1 AI2 AI2+ Note You must use 2-wire ferrules to create a secure connection when connecting more than one wire to a single terminal on the NI 9232 with screw terminal. Each channel has a terminal to which you can connect a signal source. The AI+ terminal of the connector provides the DC excitation, when enabled, and the positive input signal NI 9232 Getting Started Guide National Instruments 13 connection. The AI- terminal provides the excitation return path and the signal ground reference. Table 1. Signal Descriptions Signal AI+ AI- Description Positive analog input signal connection Negative analog input signal connection Connecting Signal Sources You can connect ground-referenced or floating signal sources to the NI If you make a ground-referenced connection between the signal source and the NI 9232, make sure the voltage on the AI+ and the AI- connections are in the channel-to-earth safety voltage range to ensure proper operation of the NI Refer to the device datasheet on ni.com/manuals for more information about operating voltages and overvoltage protection. 14 ni.com NI 9232 Getting Started Guide Figure 3. Connecting a Grounded Signal Source Signal Source + AI+ AI Common Mode Voltage NI 9232 Figure 4. Connecting a Floating Signal Source Signal Source + AI+ AI NI 9232 Integrated Electronic Piezoelectric (IEPE) Sensors The NI 9232 provides an IEPE excitation current for each channel to measure the IEPE sensors. Typical IEPE sensors have NI 9232 Getting Started Guide National Instruments 15 a case that is electrically isolated from the IEPE electronics. As a result, connecting the sensor to the NI 9232 results in a floating connection even though the case of the sensor is grounded. Wiring for High-Vibration Applications If your application is subject to high vibration, NI recommends that you follow these guidelines to protect connections to the NI 9232 with screw terminal: Use ferrules to terminate wires to the detachable connector. Use the NI 9971 backshell kit. 16 ni.com NI 9232 Getting Started Guide Where to Go Next CompactRIO NI CompactDAQ NI 9232 Datasheet NI 9232 Datasheet NI-RIO Help NI-DAQmx Help LabVIEW FPGA Help LabVIEW Help RELATED INFORMATION C Series Documentation & Resources ni.com/info cseriesdoc Located at ni.com/manuals NI 9232 Getting Started Guide Services ni.com/services Installs with the software National Instruments 17 Worldwide Support and Services The NI website is your complete resource for technical support. At ni.com/support, you have access to everything from troubleshooting and application development self-help resources to and phone assistance from NI Application Engineers. Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, and other services. Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. 18 ni.com NI 9232 Getting Started Guide NI corporate headquarters is located at North Mopac Expressway, Austin, Texas, NI also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support or dial ASK MYNI ( ). For telephone support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, addresses, and current events. NI 9232 Getting Started Guide National Instruments 19 Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/ export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR , DFAR , and DFAR National Instruments. All rights reserved E-01 Dec15
Related Search
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks